ASME - Thickness Flat unstayed heads covers blind Flanges
Thickness Flat unstayed heads covers blind Flanges
ASME - Thickness Flat unstayed heads covers blind Flanges
The thickness of a blank unstayed dished
head with the pressure on the concave side, when it is a
segment of a sphere where
L = radius to which the head is dished, measured on
the concave side of the head
P = maximum allowable working pressure (hydrostatic
head loading need not be included)
S = maximum allowable working stress, using values
given in Section II, Part D, Subpart 1, Table 1A
t = minimum thickness of head
w = weld joint strength reduction factor per PG-26