ASME: Vertical Fire Tube Boiler- Longitudinal Pitch between Staybolts
ASME_Vertical_Fire_Tube_Boiler_Longitudinal_Pitch_Staybolts
ASME: Vertical Fire Tube Boiler- Longitudinal Pitch between Staybolts
    A furnace for a vertical firetube boiler
    38 in. (970 mm) or less in outside diameter that requires
    staying shall have the furnace sheet supported by one or
    more rows of staybolts, the circumferential pitch not to
    exceed 1.05 times that given by the equation in PG-46.
    The longitudinal pitch between the staybolts shall not
    exceed that given by the following equation:
    L = longitudinal pitch of staybolts
    P = maximum allowable working pressure
    R = outside radius of furnace
    t = thickness of furnace sheet
    When values by this formula are less than the circumferential
    pitch, the longitudinal pitch may be as large as
    the allowable circumferential pitch.