Boiler Efficiency and Combustion Calculations
|
|
|
|
|
|
|
|
|
|
|
|
|
Efficiency Details(GCV): |
|
|
|
|
|
|
|
|
Gas composition By Volume: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Data Units: MKS,SI,FPS : solid/liquid-Weight percent, Gas fuel-vol percent; Calorific Value-MKS-kcal/kg, SI-kj/kg, FPS-BTU/lb
|
MKS Units: Temp-°C; Conductivity-Kcal/Hr/M/C; Dyn. Viscosity-Kg/M/S; Kin.Viscosity-m²/S; Sp.Heat-Kcal/Kg/C; Density-Kg/m³; Pressure - Kg/cm²;Calorific Value-kcal/kg
|
Boiler Efficiency
What is this�
The program calculates the Boiler efficiency for different fules.
Why do you need this
Boiler efficiency calculations are first step for designing Boilers, estimating fuel consumption and sizing Boiler auxiliaries like ID Fan, FD Fan, SA Fan. The gas composition and flow rates are useful for sizing pollution control equipment like ESP, Wet scrubbers, bag filters ..etc
Input/Output Data
User can select any one of the Units and then select the fuel and furnish other details like excess air. Once the user clicks the RUN>> button, the software carryout combustion , efficiency calculations and displays the result. The output data consists of exhaust gas composition by volume , Gross Calorific Value,Net Calorific Value,Unit Wet Air Efficiency Fired(GCV), Efficiency Burnt(GCV), Efficiency(NCV),Efficiency Details(GCV),Dry Gas Loss, Moisture Loss(Produced+Fuel) and Moisture in Air.
Areas where these calculations are useful and for whom
This data is useful for design engineers, boiler practicing engineers, consultants and boiler operating engineers.
|
|